Hersteller: APC

APC ACRC301H Rack-Kühlgerät

€17072,56 inkl. Steuer
exklusive Versand
InRow RC, 300mm, Chilled Water, 208-230V, 50/60Hz - HT
Artikelnummer: 270B200
Herstellernummer: ACRC301H
Verfügbarkeit: Auf Lager
Active Airflow Control<br>Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.<br><br>Dew point monitoring<br>Prevents condensation from forming inside the enclosure by dissuading access when the external dew point is above supply air temperature.<br><br>Hot swappable fans<br>Allows system to remain operational if a fan replacement is required.<br><br>Leak detection<br>Notifies user in the event of a water leak within the coiling unit.<br><br>Top and bottom chilled water connections<br>Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.<br><br>Washable filters<br>Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.<br><br>InRow Chilled Water CoolingFeatures & Benefits<br><br>Availability<br><br>Dual A-B power inputs<br>Draws power from the UPS for power protection with dual feeds for redundancy.<br><br>Rack inlet control<br>Rack inlet control guarantees inlet temperature to IT equipment.<br><br>Top and bottom chilled water connections<br>Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.<br><br>Active response controls<br>Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.<br><br>Predictable cooling<br>Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.<br><br>Serviceability<br><br>Easy service access<br>Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.<br><br>Agility<br><br>Modular design<br>Modular design provides scalable solutions to add cooling as demand increases.<br><br>Scaleable densities<br>Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.<br><br>Casters<br>Provides flexibility to move the unit to wherever cooling is required.<br><br>Manageability<br><br>Real-Time Capacity Monitoring<br>Real-time display of current and available cooling.<br><br>Microprocessor controller<br>Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.<br><br>Building management system integration<br>Send alarms and data points allowing you to manage critical building infrastructure from a single system.<br><br>Total Cost of Ownership<br><br>Row-based architecture<br>Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.<br><br>Variable speed fans<br>Variable speed fans reduce energy consumption during off-peak cooling periods.
Active Airflow Control<br>Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.<br><br>Dew point monitoring<br>Prevents condensation from forming inside the enclosure by dissuading access when the external dew point is above supply air temperature.<br><br>Hot swappable fans<br>Allows system to remain operational if a fan replacement is required.<br><br>Leak detection<br>Notifies user in the event of a water leak within the coiling unit.<br><br>Top and bottom chilled water connections<br>Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.<br><br>Washable filters<br>Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.<br><br>InRow Chilled Water CoolingFeatures & Benefits<br><br>Availability<br><br>Dual A-B power inputs<br>Draws power from the UPS for power protection with dual feeds for redundancy.<br><br>Rack inlet control<br>Rack inlet control guarantees inlet temperature to IT equipment.<br><br>Top and bottom chilled water connections<br>Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.<br><br>Active response controls<br>Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.<br><br>Predictable cooling<br>Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.<br><br>Serviceability<br><br>Easy service access<br>Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.<br><br>Agility<br><br>Modular design<br>Modular design provides scalable solutions to add cooling as demand increases.<br><br>Scaleable densities<br>Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.<br><br>Casters<br>Provides flexibility to move the unit to wherever cooling is required.<br><br>Manageability<br><br>Real-Time Capacity Monitoring<br>Real-time display of current and available cooling.<br><br>Microprocessor controller<br>Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.<br><br>Building management system integration<br>Send alarms and data points allowing you to manage critical building infrastructure from a single system.<br><br>Total Cost of Ownership<br><br>Row-based architecture<br>Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.<br><br>Variable speed fans<br>Variable speed fans reduce energy consumption during off-peak cooling periods.